Installation Manual Page 9
8020 Queenair Drive, Gaithersburg, MD 20879 USA • phone: 301 921 4120 • fax: 301 963 3050
©2011 Cathode Lighting Systems Inc.
FCLS-Slim Manual 8-11
CONNECTION TO THE BRANCH CIRCUIT
Each luminaire or luminaire array (depending upon the requirements of the lighting installation) are powered from a
branch circuit. A splice box (for each circuit) is installed in the cove. The #14 jumper cable extending from the end
of the luminaire is wired directly into the splice box, which is wired (in conduit) to the branch-circuit breaker panel.
Splice box may either be a Handy Box or a 1900 box. If the jumper cable is not long enough to reach the splice
box, #14 AWG 3-conductor SJO cable may be supplied by the installing electrical contractor.
T ypical cove mounted installation (perspective view).
Schematics of typical mounting configuration & splice box location
Detail of FCLS-Slim luminaire installed within a cove, showing
the splice box surface-mounted inside the cove.
Detail of FCLS-Slim luminaire installed within a cove,
showing the splice box flush-mounted inside the cove.
Contractor-provided splice box, with jumper
cable installed.
Branch circuit wiring, in listed conduit.